Anycubic 3D Printers Settings Phrozen 3D Printers Settings Elegoo 3D Printers Settings Flashforge 3D Printers Settings Wanhao 3D Printers Settings Epax 3D Printers Settings Longer 3D Printers Settings Creality 3D Printers Settings Nova3D Printers Settings Peoply 3D Printers Settings Zortrax 3D Printers Settings
- Digital Jewelry Production
- Digital Dental Production
- Blog
Table of Contents
Gingiva Resin Instructions for Use
1- Indented Use
Gingive Resin is a dental resin developed to simulate gingival-like structure on a dental model. Gingiva Resin compatible with either 385 and 405nm 3D printer devices.
2- Contraindications
Power Resins Gingiva Resin should not be used for any purpose other than just applications on a dental model. Any deviation from this instruction for use may adversely affect the chemical and physical quality of the 3D product. In case of allergic reaction, please consult a medical doctor.
3- Safety Instructions
To ensure optimum further processing, please carefully read the information contained in the instructions for use. Misuse and failure to observe information can have a detrimental effect on quality. Nitrile gloves, goggles and a jacket should be worn as a means of protection when working with resin.
The safety instructions and precautions outlined in the Gingiva model resin operating instructions and safety data sheet will apply to the removal of liquid resin and uncured resin from the model.
A dust mask should also be worn due to possible dust formation in post-press processes.
4- Side Effects and Precautions
In liquid form;
Inhalation
Irritates the respiratory organs. High concentrations can lead to irritation of the respiratory passages, dizziness, headaches, and loss of consciousness.
Skin contact
Sensitization or irritation is possible from contact with the skin. Repeated and/or extended skin contact can cause inflammations.
Eye contact
High air concentrations can lead to eye irritations. If on eye wash with plenty of water. Remove your contact lenses. If skin irritation or rash occurs: Get medical advice/attention
Swallowing
Low oral toxicity; ingestion can, however, lead to irritation of the gastrointestinal tract.
Power Resins Dental Model LT Resin
Hazardous Component: Phenylbis (2,4,6-trimethyl benzoyl)-phosphine oxide
Color | Pink |
Viscosity | 1145 mPa.s |
Density | 1.1 g/cm3 |
Warning!
In liquid form;
P280 Wear protective gloves, glass, and clothing while using. Advised to use nitryl gloves.
H319 May cause eye irritation.
P305+P351+P338 If on eye wash with plenty of water. Remove your contact lenses. If skin irritation or rash occurs: Get medical advice/attention
Light sensitive! Keep open containers away from direct sunlight or room light.
Keep out of reach of children.
Keep away from food.
Safety instructions as per MSDS
• Avoid inhaling aerosol
• Wear protective gloves/eye protection
• Call a doctor/physician if you feel unwell
• If skin irritation/rash occurs: get medical advice/attention
• If eye irritation persists: get medical advice/attention
• Dispose of contents / container as per local and national regulations
5- General Information on Handling
Delivery
Power Resins Gingiva Resin is supplied in light-tight, sealed bottles.
Please check the following points on receipt of the goods:
• Integrity of the bottle / pack
• Quantity
• Color
• Shipping documents and designation
Storage Conditions
Keep the resin bottle range of 22-27 OC / 71-80 OF. The minimum shelf life date printed on the product must be observed. Store this product in tightly closed containers in a properly vented storage area under dry conditions away from sparks and open flames. Avoid the material to direct sunlight. Shelf life is 1 year from production. Perfect processing cannot be guaranteed if materials which have exceeded their minimum shelf life date are used. For additional information, please see Material Safety Data Sheet.
6- Processing
Processing
Power Resins Gingiva Resin is designed to work with all LCD and DLP 3D printers. See the %% section on powerresins.com for optimization databases.
Cleaning:
a. Allow the model to clean for 3 minutes in compartment 1 of the MEDIFIVE washer containing ethanol solution (96%). After the process is complete, dry the model with a spray air gun.
b. Allow the model washed and dried in compartment 1 to be cleaned in compartment 2 of the MEDIFIVE washer containing ethanol solution (96%) for 3 minutes. After the process is complete, dry the model with a spray air gun.
Do not exceed the 6-minute total cleaning procedure as this may cause deterioration of printed objects.
Hint: Resin residues can also be removed using a brush moistened with ethanol (96%).
Finishing:
The completely cleaned print objects must be post-cured to attain the required material properties and biocompatibility.
7- Post-Curing
Caution: Post-curing outside of the recommended settings can lead to suboptimal mechanical and biocompatibility properties. Post-cure only in accordance with official recommendations from Power Resins for the best possible results.
Recommended post-curing
2x2000 flash on Otoflash G-171 curing device
30 minutes in a MEDIFIVE curing room at 3rd-degree light intensity
The mechanical values to be obtained when the recommended post processes are applied are given in the table below.
Wavelength | 405 nm |
Tensile strength | 2.2 MPa |
Shore Hardness D | >80 |
8- Supporting Documents